PERFORMANCE ENHANCEMENT OF ELECTROSTATIC PRECIPITATOR (ESP) BY AMMONIA INJECTION IN THE FLUE GAS

ESP performance parameters before and after ESP fine tuning

(with ammonia injection)

Sr.N.

Parameters

SG-3 Before Fine tune

SG-3 After Fine tune

SG-3 After Further Fine tune

1.

Flue gas temp. oC

147

145

151

2.

Flue gas flow Nm3/sec

42.72

48.61

48.61

3.

Flue gas humidity

(volume %)

6.4

6.4

7.0

4.

Steam generation te/hr

204

199

204

5.

Coal consumption te/hr

54.6

46.0

54.6

6.

Ammonia flow kg/hr

15

15

15

8.

SPM in the flue gas mg/Nm3

140

70

20

The results obtained from Ammonia Dosing System has been exceptionally good and the operation of the system has given confidence that the SPM level in the exit flue gas can be maintained as low as possible by adjusting the ammonia feed concentration. The ammonia dosing along with the fine tuning of the ESP will result in controlling the SPM level to as low as 20-70 mg/Nm3 in line with the latest guidelines for making the stacks smokeless. The technology developed by HWB can be passed on to other power generating units.

 